Function
- Temperature automatic control for removing frost and for protecting the frozen rupture
in the cold storage or freezing systems
- Easy to install at the small or narrow space as slim shape .Small size with high contacting capacitance
- Available waterproof and dustproof types with welding vinyl tube on the part
Schematic
Safety Certificates
UL File No. E126365
TUV File No. B 07 04 62807 002
Specification |
Rated Current |
AC 125V / 10A, 250V / 5A |
Temperature Range |
-20℃ to +60℃ |
Reset_Temperature |
10℃ Min. |
On/Off Differential |
Min. 10℃, Normal 15 to 25℃ |
Temp. Tolerance |
Operating or Reset Temp. ±3℃ Min. (Standard ±5℃) |
Life Cycle |
100,000 cycles Min. at rated load |
Dielectric Withstand |
AC 1.8kV for 1second |
Insulation Resistance |
100MΩ Min. |
Internal Resistance |
100mΩ Max. (including lead wires resistance) |
Lead Wire Spec. |
UL1015 AWG18 STANDED. |
Fuse Temperature Range |
72℃ to +84℃ |